Electrical characteristics
Recommended operational characteristics:
parameter | min | max | unit | note |
supply voltage | 9 | 30 | V | Voltage range at which the ASU module performs all the declared functions |
current consumption |
| ??? | mA | It depends on the number of active channels, the total current of the loads, the supply voltage, the activity of the CAN bus. Typical value for the case of eight active channels and a voltage of 24 V is about ???mA. If all channels are inactive, the current consumption does not exceed 10 mA. |
Total output current |
| 120 | A | Depends on the ambient temperature. |
current per output |
| 15 | A | Depends on the ambient temperature and total current |
Critical operational characteristics:
parameter | max | unit | note |
supply voltage | 36 | V |
|
Reverse voltage | -32 | V |
|
total output current | 150 | A | Depends on the ambient temperature. For consultation, contact the NSE. |
current per output | 20 | A | Depends on the ambient temperature. Short-term inrush currents can reach higher values. For consultation, contact the NSE. |